On this page
What a heavy-metal section should list
A heavy-metal result is only readable if the report gives enough context to interpret each number. In a complete report the metals section names each metal, states a result, a unit, a limit that defines pass or fail, and the lowest amount the method could detect or report. Many reports test the same four elements: lead, arsenic, cadmium and mercury. That list is common practice, not a rule printed in any source we reviewed, and the exact set can differ. If a report lists only one or two, ask why.
FDA’s manufacturing rule is the reason these results exist at all. Makers must set specifications that include limits on contamination that may adulterate the finished batch,1 and must verify finished batches against them, either on every batch or on a sound statistical sample.2 The rule says the limits must exist and be checked. It does not give a number for any metal in this text, and the regulator and pharmacopeia pages that publish numeric limits (California’s OEHHA and USP) could not be opened for this article, so no limit values are quoted here. That is why the report should say what limit it used.
Units and conversion
Most confusion in metals reports comes from units. Four labels turn up, and three of them mean the same thing:
| Unit as printed | Same as | Scale |
|---|---|---|
| ppm (parts per million) | mg/kg, or µg/g | 1 part in 1,000,000 |
| ppb (parts per billion) | µg/kg, or ng/g | 1 part in 1,000,000,000 |
| µg/g | ppm | 1 microgram per gram |
| mg/kg | ppm | 1 milligram per kilogram |
Two conversions are enough:
- 1 ppm = 1 µg/g = 1 mg/kg.
- 1 ppb = 0.001 ppm = 1 ng/g.
So a result of 50 ppb equals 0.05 ppm equals 0.05 µg/g. A report that lists a limit in ppm and a result in ppb is not wrong, but you have to convert before comparing, and mistakes at this step are common. If you cannot tell which unit applies to a number, that is a reason to ask.
Per-serving arithmetic
Limits are often set per gram of product, but you take a daily amount, so the figure that matters to you is micrograms per day. The arithmetic is one multiplication:
micrograms per day = result (µg/g) × grams of product taken per day
This is arithmetic only. It shows what a reported result would add up to, and it does not say whether that amount is acceptable, because acceptability depends on a limit the report must supply.
Hypothetical worked example (invented numbers, not real data). Suppose a report lists lead at 0.08 µg/g in a finished AHCC product, and the label directs 3 grams of product per day.
- 0.08 µg/g × 3 g/day = 0.24 µg per day.
If the label’s serving is two capsules weighing 1 g of blend in total, with a suggested maximum of three servings a day as on one verified AHCC label,5 then the daily amount of product is 3 g at the top of that range, and the figure is the same.
Two things to notice. First, the conversion should use the weight of the product the result describes (ingredient, blend or capsule contents), not the weight of the AHCC extract alone, because the contaminants are measured in whatever sample was tested. If the result is for powder in a capsule and a capsule weighs a different amount, use the capsule contents weight. The page on capsule weight versus AHCC amount deals with the difference. Second, if you take less than the label directs, the daily amount scales down proportionally; if you take more, it scales up.
Reporting limits and ND
The most misread entries in a metals table are “ND” and “<”.
- ND (not detected) means the instrument did not see the metal at or above the method’s detection level. It does not mean zero.
- “< 0.05 µg/g” means the result was below a reporting limit of 0.05 µg/g. The true value could be anywhere from zero up to just under that figure.
The reporting limit (sometimes labeled LOQ, limit of quantitation, or RL) is therefore a critical column. A report with a high reporting limit can say “ND” and still be uninformative. Example, again hypothetical: if the pass limit for a metal were 0.5 µg/g and the reporting limit were 1.0 µg/g, an “ND” result would not show compliance, because the method could not see anything below 1.0. A good report has a reporting limit comfortably below the pass limit. As a rough test, check that the reporting limit is a small fraction of the limit; if it is equal or larger, ask the brand.
Per-serving arithmetic with a “less than” result works as an upper bound. A result of < 0.05 µg/g at 3 g/day means no more than 0.15 µg per day of that metal from this lot, assuming the reporting limit is accurate.
Whose limit applies
A pass mark means little unless you know who set the limit. Three possibilities cover most reports:
- The maker’s own specification. Part 111 requires each maker to set limits for contaminants.1 The maker may choose the limit, so a pass against the company’s own line is only as strict as the line.
- A published reference limit from a pharmacopeia, a regulator or a state program. The report should name it (for example “USP general chapter” or a state program). The sources for specific numbers could not be opened for this page, so check the named document directly.
- A testing program’s criteria, if the report comes from an independent program. ConsumerLab says it tests products it buys at retail, whenever possible for identity, strength, purity and disintegration, though the page does not list which contaminants.4
If the report says only “Pass” with no limit named, you cannot judge the number. The structure of this problem is the same as in any certificate of analysis: result, specification, status, and the specification is the column that does the work.
Hypothetical report walkthrough
The table below is hypothetical. It is invented to practice with and is not a report for any real product or lot.
| Metal | Method | Reporting limit (µg/g) | Result (µg/g) | Stated limit (µg/g) | Per 3 g/day (µg) |
|---|---|---|---|---|---|
| Lead | ICP-MS | 0.02 | 0.06 | 0.5 | 0.18 |
| Arsenic (total) | ICP-MS | 0.02 | 0.15 | 1.0 | 0.45 |
| Cadmium | ICP-MS | 0.02 | < 0.02 | 0.3 | up to 0.06 |
| Mercury | CV-AAS | 0.01 | ND | 0.1 | less than 0.03 |
How to read it, row by row: lead measured at 0.06 against a limit of 0.5, so about an eighth of the limit, and 0.06 × 3 = 0.18 µg a day. Arsenic is reported as “total,” which is a prompt for a question, because arsenic exists in more than one chemical form and a total figure does not say which. Cadmium is below the reporting limit, so the per-day figure is an upper bound. Mercury is “ND” with a reporting limit of 0.01, well below the stated limit of 0.1, so the “ND” is informative. Then run the last checks: is the lot the one on your bottle, is the sample the finished capsule or the raw material (the distinction matters here), and was the work done by a named laboratory? A laboratory can be accredited to ISO/IEC 17025, which ISO describes as the international standard for testing and calibration laboratories;7 ILAC defines accreditation as independent evaluation against recognised standards.6 The report should name the accreditation body so the scope can be looked up.
What no source we reviewed shows
Everything above is a method for reading a report. It is not a statement about AHCC products. No source we reviewed publishes heavy-metal results for AHCC, and the ConsumerLab AHCC page we opened reports no test results for any AHCC product.3 The HPV trials do not report contaminant testing of the product they used, so there is no study-side number to compare a bottle against.
One label statement is worth knowing about because readers sometimes ask. One verified AHCC label says the mycelia are grown in rice bran extract.5 Whether growth medium affects metal content in AHCC is not addressed by any source we reviewed, so this page draws no conclusion from it. A report that includes heavy metals and arrives with a lot number, a named laboratory, a reporting limit and a stated limit is the practical way to replace speculation with a number for the lot you hold. If the brand has such a report, ask for it; if it does not, that absence is itself the answer to “has this lot been checked for metals?”
References
- 21 CFR 111.70 - What specifications must you establish?. Legal Information Institute, Cornell Law School (text of the FDA regulation). US · Checked 2026-11-25
- 21 CFR 111.75 - What must you do to determine whether specifications are met?. Legal Information Institute, Cornell Law School (text of the FDA regulation). US · Checked 2026-11-25
- AHCC (Active Hexose Correlated Compound): Health Benefits and Safety. ConsumerLab.com. 2022. US · Checked 2026-11-25
- About ConsumerLab.com. ConsumerLab.com. US · Checked 2026-11-25
- AHCC (Active Hexose Correlated Compound) 500 mg, Source Naturals (NIH Dietary Supplement Label Database, label 181753). NIH Office of Dietary Supplements. US · Checked 2026-11-25
- About ILAC. International Laboratory Accreditation Cooperation. International · Checked 2026-11-25
- ISO/IEC 17025:2017 - General requirements for the competence of testing and calibration laboratories. International Organization for Standardization. 2017. International · Checked 2026-11-25